Check out our new preprint on an integrated pipeline combining in situ #cryo-ET with MALDI #MSImaging for single-cell identification and classification from previously analysed EM-grids.
Link: www.biorxiv.org/content/10.1...

19.09.2025 18:07 β€” πŸ‘ 55    πŸ” 14    πŸ’¬ 1    πŸ“Œ 2
mzio – Accelerate Scientific Discoveries

Only used it for small molecule and imaging datasets so far: mzmine mzio.io It reads timstof files natively and is super fast compared to data analysis.

23.07.2025 06:28 β€” πŸ‘ 1    πŸ” 0    πŸ’¬ 1    πŸ“Œ 0

As permanent lock-mass or injectable?

03.04.2025 18:53 β€” πŸ‘ 0    πŸ” 0    πŸ’¬ 1    πŸ“Œ 0

That's quite a difference! - Wanted to test that for our Tims files, but the automatic file conversion in RawBeans produces insanely large mzml files that crash later on. Is there a specific setting / how do you convert the raw files for that?

01.04.2025 16:13 β€” πŸ‘ 1    πŸ” 0    πŸ’¬ 1    πŸ“Œ 0

All of this was a preview on ASMS releases this year, but no idea when it'll practically be available...

27.03.2025 10:08 β€” πŸ‘ 1    πŸ” 0    πŸ’¬ 0    πŸ“Œ 0

Bruker showed a lot on their DE/EU user meeting already:
-Entry level metabolomics TIMS; with low mass capable quad
-Biopharma (Omnitrap-)TIMS
-AIP ion processor upgrade (improved ion transfer CC->TOF)
-More robust nanoLC (nanoResolve?), an upgraded nE2 with ceramic valves, AS pump & inline filters

27.03.2025 09:17 β€” πŸ‘ 3    πŸ” 1    πŸ’¬ 1    πŸ“Œ 0

It elutes rather late in the gradient / wash step - not sure if it would come off an Evotip. For our workflow it also gets filtered out as a +1 charge in ion mobility.

19.03.2025 10:35 β€” πŸ‘ 1    πŸ” 0    πŸ’¬ 1    πŸ“Œ 0

An easy way to test is either by trap injection (higher equilibration volume for flushing out air) or to set the air gaps to "0" in the advanced settings

15.01.2025 15:13 β€” πŸ‘ 1    πŸ” 0    πŸ’¬ 2    πŸ“Œ 0

Does it only occur during runs or also with idle flow at these solvent compositions?
Did you recently update the LC-Plugin? We've had similar issues after that (2.1 SR2) and found a software bug, where to much air is drawn during the injection, which creates spray instabilities.

15.01.2025 15:11 β€” πŸ‘ 0    πŸ” 0    πŸ’¬ 1    πŸ“Œ 0